Asbestos Blockplans
University Park Campus

Known Buildings With Asbestos Containing Ceiling/Wall Plaster, Spray-on Fireproofing/Coatings, Ceiling Tiles and Transite Panels

DO NOT PRINT THIS LISTING AND ASSUME CHANGES NEVER OCCUR. UPDATES ARE ADDED CONSTANTLY.

UPDATE (3/3/03) - IF A BUILDING IS NOT SHOWN ON THIS LISTING, DO NOT ASSUME THERE IS NO ASBESTOS IN THE BUILDING.

These Asbestos Blockplans DO NOT include the following asbestos containing materials, which are commonly found in most University buildings:

  • Thermal insulations such as pipe, boiler, tank, or duct insulation; these are assumed to contain asbestos unless they are obviously fiberglass or foam rubber.
  • Resilient floorings (i.e. 12"x12" and 9"x9" Floor Tile, Linoleum, etc.); these are also assumed to contain asbestos
  • Soapstone Lab Bench Tops are also assumed to contain asbestos.
Note: Many of these materials are above drop ceilings or encased in walls and are not readily visible.

If needed, more specific locations of asbestos containing materials can be obtained by calling Environmental Health and Safety at 865-6391 (863-1111 after 5 P.M.).

For more information on recognition and identification of other common asbestos containing materials and regulations, see the Identification/Quick Reference for Asbestos-Containing Building Materials link on the EHS Asbestos Webpage.


Agricultural Engineering - Troweled-on ceilings

Agricultural Seed – Transite panels. (Blockplans not created for this building.  The Transite panels are found throughout the facility).

Althouse Lab – Ceiling tiles

ARL - Spray-on fireproofing (above drop ceilings), Asbestos wallboard. (Blockplans kept at EHS)

Arts - Troweled-on ceilings (some above drop ceilings) (Ceiling tiles in affected areas cannot be moved or replaced without contacting EHS first).

Borland Lab - Troweled-on ceiling material (some above drop ceilings) (Ceiling tiles in affected areas cannot be moved or replaced without contacting EHS first).

Boucke - Troweled on ceilings and wall trim (wall trim in corridors only)

Brumbaugh Hall – Spray-on (textured) ceiling paint. (Blockplans not created for this building.  The textured paint is easily found and recognized.)

Burrowes - Troweled-on ceilings (some above drop ceilings) (Ceiling tiles in affected areas cannot be moved or replaced without contacting EHS first).

Business Administration II - Troweled-on ceilings (some above drop ceilings) (Ceiling tiles in affected areas cannot be moved or replaced without contacting EHS first).

Carpenter - Spray-on fireproofing on I-beams (exposed only in crawlspace; others assumed to be enclosed in walls) (Ceiling tiles in affected areas cannot be moved or replaced without contacting EHS first).

Cedar – Ceiling Tiles (Ceiling tiles in affected areas cannot be moved or replaced without contacting EHS first).

Centralized Biological Lab - Transite ceiling tiles (in corridors only)

Chambers - Troweled-on ceilings

Chandlee Lab - Spray-on fireproofing, Transite wall panels in corridors, Ceiling tiles (Ceiling tiles in affected areas cannot be moved or replaced without contacting EHS first).

Computer - Spray-on fireproofing (some above drop ceilings) (Ceiling tiles in affected areas cannot be moved or replaced without contacting EHS first).

Dairy Barns C, D, F – Transite ceiling and wall panels throughout facilities

Davey Lab - Troweled-on ceiling (Room 12 only)

Eisenhower Auditorium - Spray-on fireproofing (some above drop ceilings) (Ceiling tiles in affected areas cannot be moved or replaced without contacting EHS first).

Eisenhower Chapel - Troweled-on ceilings

Electrical Engineering West - Troweled-on ceilings (some above drop ceilings) (Ceiling tiles in affected areas cannot be moved or replaced without contacting EHS first).

Ferguson - Troweled-on ceilings and walls (wall material only in Room 204)

Fisher Hall – Spray-on (textured) ceiling paint. (Blockplans not created for this building.  The textured paint is easily found and recognized.)

Forest Resources Lab - Spray-on ceilings

Frear South – Ceiling tiles (Ceiling tiles in affected areas cannot be moved or replaced without contacting EHS first).

Gypsy Moth Research – Transite wall panels. (Blockplans not created for this building.  The Transite panels are found throughout the facility).

Hamilton Hall - Troweled-on ceiling material above sliding closet door tracks in Student Rooms.

Hammond (Kunkle Lounge Area) – Transite floor decking.

Headhouse II – Transite ceiling and wall panels.

Henderson North – Ceiling tiles (Ceiling tiles in affected areas cannot be moved or replaced without contacting EHS first).

Kern - Spray-on fireproofing (above drop ceilings)(Ceiling tiles in affected areas cannot be moved or replaced without contacting EHS first).

Land and Water Research - Spray-on fireproofing (Mechanical Room only).

Mastitis Research Barn – Transite wall and ceiling panels. (Blockplans not created for this building.  The Transite panels are found throughout the facility).

Moore - Spray-on fireproofing (some above drop ceilings) (Ceiling tiles in affected areas cannot be moved or replaced without contacting EHS first).

Mushroom Research - Transite ceiling panels, Ceiling tiles (Ceiling tiles in affected areas cannot be moved or replaced without contacting EHS first).

Mushroom Test Demo Facility - Transite duct.

Music - Troweled-on ceilings.

Osmond Lab - Transite wall panels in corridors.

Oswald (Liberal Arts) Tower – Troweled-in fire-stop material in voids between floors (under unit ventilators). (Blockplans not created for this building.  The white fire-stop is easily found and recognized above drop ceilings or under unit ventilators.  Ceiling tiles above unit ventilators cannot be moved or replaced without contacting EHS first).(Added August 19, 2004)

Pattee Library - Ceiling patch areas in Old Central Wing, Spray-on fireproofing (Old East Mechanical Room).

Pinchot Hall – Spray-on (textured) ceiling paint. (Blockplans not created for this building.  The textured paint is easily found and recognized.)

Pond Lab - Transite duct (some above drop ceilings) and wall (only in Room 107).

Rackley - Spray-on fireproofing (above drop ceilings) (Ceiling tiles in affected areas cannot be moved or replaced without contacting EHS first).

Rec Hall - Troweled-on ceilings (some above drop ceilings). (Ceiling tiles in affected areas cannot be moved or replaced without contacting EHS first).

Research Center Storage I – Transite wall panels. (Blockplans not created for this building.  The Transite panels are found throughout the facility).

Research Unit A – Transite wall/window panels. (Blockplans not created for this building.  The Transite panels are found only around exterior windows).

Research Unit B – Transite wall/window panels. (Blockplans not created for this building.  The Transite panels are found only around exterior windows).

Research Unit C – Transite wall/window panels. (Blockplans not created for this building.  The Transite panels are found only around exterior windows).

Ritenour - Troweled-on ceilings (some above drop ceilings) (Ceiling tiles in affected areas cannot be moved or replaced without contacting EHS first).

Sackett (Kunkle Lounge Area) – Transite floor decking.

Shields - Spray-on fireproofing.

Sproul Hall – Spray-on (textured) ceiling paint. (Blockplans not created for this building.  The textured paint is easily found and recognized).

Swine Research – Transite panels. (Blockplans not created for this building.  The Transite panels are found throughout the hog pen area).

Tener Hall – Spray-on (textured) ceiling paint. (Blockplans not created for this building.  The textured paint is easily found and recognized).

Thompson Hall - Troweled-on ceiling material above sliding closet door tracks in Student Rooms.

Visual Arts - Troweled-on ceiling.

Whitmore - Troweled-on ceilings (some above drop ceilings), Transite wall panels in corridors (Ceiling tiles in affected areas cannot be moved or replaced without contacting EHS first).

Willard - Troweled-on ceilings and wall trim (some above drop ceilings) (Ceiling tiles in affected areas cannot be moved or replaced without contacting EHS first.)


Created: September 20, 2002; Mike Burke
Updated: August 19, 2004; Mike Burke

For more information on PSU EHS asbestos policies, services, etc. please call (814) 865-6391 or e-mail Mike Burke.